Equalization Tank for Wastewater Treatment

Wastewater treatment processes are designed for stable and consistent flow and pollutant load. However, in real-world industrial and municipal systems, flow rates and contaminant concentrations vary significantly throughout the day. This variability can overload downstream treatment units, reduce treatment efficiency, and cause compliance failures. The solution lies in the equalization tank, also called a flow balancing tank, which absorbs these variations and provides a consistent influent stream to biological, chemical, or physical treatment units. This article provides a detailed guide to equalization tank design, covering sizing criteria, retention time, mixing and aeration requirements, instrumentation, and operational best practices.


What Is an Equalization Tank?

An equalization tank is a buffer tank in the wastewater treatment process that temporarily stores and homogenizes incoming wastewater to minimize fluctuations in flow rate and pollutant concentration.

Think of it as a shock absorber that protects downstream treatment stages from spikes in hydraulic or organic load.


Why You Need a Flow Balancing Tank

The Role of a Flow Balancing Tank in Treatment Plants

  1. Hydraulic Equalization
    – Absorbs high flow during peak hours and releases during low flow

  2. Load Equalization
    – Dilutes high BOD/COD loads, preventing biological shock

  3. Improved Process Stability
    – Protects ASP, MBR, or SBR systems from upsets

  4. Chemical Optimization
    – Enables steady dosing of coagulants, pH neutralizers, and polymers

  5. Prevents Overloading of Pumps
    – Allows consistent operation of sludge and effluent transfer pumps


Key Design Criteria for Equalization Tank

Engineering a Reliable Equalization Tank Design

Parameter Typical Range / Consideration
Daily Flow Variation Peak-to-average ratio: 1.5–3.5
Retention Time 4 – 12 hours (depends on variability)
Tank Volume Avg. hourly flow × retention time
Mixing/Aeration To avoid settling and septicity
Tank Shape Rectangular, circular, or U-shaped
Materials of Construction RCC, FRP, HDPE, MS+Epoxy depending on application

Step-by-Step Equalization Tank Sizing

Calculating Equalization Tank Design Capacity

  1. Determine peak and average flow
    Example:

    • Peak Flow = 150 m³/hr

    • Average Flow = 100 m³/hr

    • Retention time (RT) = 6 hours

  2. Calculate working volume

    Volume=Average Flow×RT=100×6=600 m3Volume = Average Flow × RT = 100 × 6 = 600\ m³

  3. Add freeboard (15–20%)

    Total Volume=600×1.15=690 m3Total Volume = 600 × 1.15 = 690\ m³

  4. Decide tank dimensions
    For a rectangular tank:

    • Depth = 4.5 m

    • L × W = Volume / Depth = 690 / 4.5 ≈ 153 m²

    • Try L = 17 m, W = 9 m (153 m²)


Mixing and Aeration in Flow Balancing Tanks

Preventing Septicity in a Flow Balancing Tank

Stagnant water leads to anaerobic conditions (septicity), especially in hot climates or food-based effluents. Mixing or aeration is necessary to:

  • Avoid settling of suspended solids

  • Prevent odor generation

  • Ensure homogeneous flow to downstream units

Options:

Method Description
Air Diffusers Low-energy aeration and mixing
Surface Aerators Ideal for shallow tanks
Mechanical Mixers Used where aeration is not required

Instrumentation and Automation

Smart Equalization Tank Design with Sensors

  • Level Sensors
    – Ultrasonic or pressure sensors to track tank fill level

  • DO Sensors
    – For aerated EQ tanks to maintain aerobic conditions

  • Flow Meters
    – At inlet and outlet for flow monitoring

  • pH and ORP Probes
    – For real-time monitoring in high-load industrial applications

  • Control Panel or PLC
    – Automates inlet pump, outlet pump, and aerator/mixer


Tank Materials and Construction

Industry Recommended Tank Type Material Options
Municipal STP RCC, open-top EQ tank RCC, MS + epoxy
Pharma & Chemicals Covered tanks with fume venting FRP, HDPE, SS
Textiles U-ground or RCC tanks MSRL, FRP, epoxy-lined
Food Processing Odor-controlled tanks SS or closed FRP tanks

Ventilation and odor control is critical for industries dealing with FOGs or organics.

Compact Effluent Treatment Plants


Inlet/Outlet Pump Control Strategy

Typical Pump Operation in a Flow Balancing Tank

  • Inlet Pumps: Controlled by upstream tank level or time cycles

  • Outlet Pumps: Flow-paced to ensure constant discharge

  • Emergency Overflow: Prevents backflow or tank breach

  • Drain & Wash Line: Required for periodic cleaning


Case Study: Equalization Tank in a Paint Manufacturing ETP (UAE)

  • Flow: 180 m³/day with peaks up to 250 m³/day

  • BOD variation: 150 mg/L to 650 mg/L

  • Tank Size: 90 m³ (6 hours retention)

  • Mixing: 2 paddle mixers with 1.5 kW each

  • Result:

    • Reduced shock load to SBR unit

    • Improved treatment efficiency by 30%

    • No odor complaints from nearby commercial units


Maintenance Best Practices

  • Inspect agitators monthly

  • Clean sediment buildup quarterly

  • Calibrate level and DO sensors bi-monthly

  • Flush aeration nozzles if using compressed air

  • Check overflow drain and scum control mechanisms


Common Issues and How to Prevent Them

Problem Solution
Sludge settling in base Install bottom mixer or air grid
Foaming during aeration Use defoamers or adjust aeration rate
Overflows during heavy rain Add overflow tank or increase freeboard
Odor in summer Use aeration + closed cover with fume scrubber

Top Global Manufacturers of Flow Balancing Tanks

  1. WesTech Engineering (USA)
    – Turnkey EQ tanks with aeration and pump controls

  2. Fluence Corp (Israel/USA)
    – Modular flow balancing tank systems with smart automation

  3. SAZ ENVIRO (India, Export Focused)
    – Custom equalization tank design
    – FRP, RCC, and MSRL tanks
    – Supplied to Kenya, Oman, Nigeria, UAE
    – Optional aeration skid, PLC panel, flow meter, and sensors included


Conclusion

An intelligently designed equalization tank is vital for achieving stable, predictable wastewater treatment performance. Whether you’re treating industrial effluents with variable BOD/COD or municipal sewage with daily load swings, a flow balancing tank ensures that downstream units operate within optimal design conditions.

With proper sizing, mixing, sensor integration, and control automation, you can eliminate process shocks, optimize chemical use, and comply with discharge regulations more consistently and cost-effectively.